Cellular Glass (National Standard)

product description

Cellular Glass is a rigid inorganic thermal insulating product, composed of uniform closed cells. It is made from pure glass and foaming agents, through high temperature foaming and annealing. It reserves the chemical stability of glass, and characterized by low density, low thermal conductivity, impermeability, no water absorption, incombustibility anti-mildew/rat, high mechanical strength but easy to cut. It can bear all kinds of chemical erosion except the hydrofluoric acid.

Properties (Comply with JC/T 647)


Physical Property

Unit

ZES   140

ZES   160

Testing Method

Density

kg/m3

140±10%

160±10%

GB/T5486

Thermal Conductivity

Avg. Value

W/(m·K)

(10℃)

0.050

0.056

GB/T 10294/

GB/T 10295

Highest Single Value

0.053

0.059

Compressive Strength

Avg. Value

MPa

1.0

0.7

JC/T 647 Appendix A

Lowest Single Value

0.7

0.50

Flexural   Strength

Mpa

≥ 0.4

≥ 0.5

JC/T 647 Appendix B

Water Vapor Permeability

ng/(pa.m.s)

≤ 0.007

≤0.05

GB/T 17146-1997 Dry   Method

Water Absorption by Vol

Vol%

≤0.5

JC/T   647 Appendix C

Service Temp

-268~+480


Linear Thermal Expansion Coefficient

1/℃

9×10-6

GB/T   7320

Dimension

mm

L:   610mm(max)


 

Product Application

It is mainly applied to the insulation for low temperature/cryogenic pipes, vessels, tanks and equipment. It can also be used in dual temperature system.

 

Packing and Storage

 (1) Carton packing, special packing is available on request.

 (2) During shipment, keep cartons tightly closed, keep stacks upright to protect from collision. If necessary, reinforcement can be applied.

 (3) Store in weatherproofing, dry and ventilated environment, no more than 6 layers stack is preferred.


 

Application and Cautions

 (1) Cellular Glass is fragile, shall be handled gently, avoid rolling or collision.

 (2) Fix cellular glass segments by stainless steel band when applied in pipe/equipment insulation.

 (3) Cut it with saw during application.